Function library, Function blocks – Lenze EVS9332xP User Manual

Page 228

Advertising
background image

Function library

Function blocks

3.5.39

Freely assignable input variables (FEVAN)

3−200

l

EDSVS9332P−EXT DE 2.0

Example 1 (only for FIX32 format with % scaling):

F E V A N 1 - I N

C 1 0 9 8

C 1 0 9 6

C 1 0 9 3
C 1 0 9 4

C T R L

+

+

C 1 0 9 5

S & H

C 1 0 9 9

F E V A N 1 - L O A D

C 1 0 9 7

C 1 0 9 0

C o d e / S u b c o d e

( C x x x x / y y y )

C 1 0 9 2

C 1 0 9 1

F E V A N 1 - B U S Y

F E V A N 1 - F A I L

F E V A N 1

C 0 4 7 2 / 1

C 0 4 7 1 . B 0

Fig. 3−153

Example of a circuit for FIX32 format with % scaling

Task:

l

C0472/1 = 1.05 %. Write this value to C0141.

Configuration:

l

Connect FEVAN1−IN (C1096) with FCODE−472/1 (19521).

l

Connect FEVAN1−LOAD (C1097/1) with FCODE−471.B0 (19521).

Parameter setting:

l

Set C1091 = 141 (

¢ C0141)

l

Set C1092 = 0 (no subcode available)

l

C1093 = calculate numerator

l

Set C1094 = 0.01 (two decimal positions)

l

Set C1095 = 0 (no offset).

Calculation:

FEVAN1–IN [%]

@

1

10000

@ 16384

100

@ C1093

C1094

) C1095 + C0141 [%]

Scaling factor

Scaling factor

Control:

l

Set C0471.B0 = 1 (

¢ 00000001h) so that the data are transmitted to the target code.

Example for converting to C1093:

1.05 %

@ 10000 @ 100

16384

@ C1094 @

1

1.05 %

+ C1093 + 0.6103

FEVAN1−IN

Setpoint in C0141

Display:

l

C0141 = 1.00 %