Positioning control

3.4.8

Homing

3−55

l

EDSVS9332P−EXT DE 2.0

3.4.8.9

Homing modes 10 and 11

Purpose

l

Homing in absolute positioning mode (C1210 = 0, 2).

l

Use of touch probe if the index pulse does not appear at the same place in a reproducible
form due to the mechanical constellation. The index signal can also be mechanically shifted
after a motor replacement.

9300pos030

Mode 10: Traversing direction to positive POS−LIM−POS

Traverse in positive direction up to POS−LIM−POS, reverse there and reference to TP (case

0). During

reversing the limit switch must always be assigned!

l

Move to positive end of travel range limit switch in positive direction with homing speed
C1242.

l

Reverse and move in negative direction to the reference point via touch probe with homing
speed C1242 or C1241 (depending on the setting in C1216, see second homing speed).

l

If the drive is positioned on the positive end of the travel range limit switch before homing, it
directly travels in negative direction (case

1).

l

The reference point is at touch probe + home position C1227.

Monitoring P02 does not respond!