4 measuring systems, Measuring systems, Function library – Lenze EVS9332xP User Manual

Page 62: Positioning control

Advertising
background image

Function library

Positioning control

3.4.4

Measuring systems

3−34

l

EDSVS9332P−EXT DE 2.0

3.4.4

Measuring systems

Purpose

l

Limitation of the traversing and determination of reference points for positioning.

9300POS006

0

L i m i t p o s i t i o n

n e g a t i v e

L i m i t p o s i t i o n

p o s i t i v e

C 1 2 2 4

C 1 2 2 3

0

a c t . t a r g e t p o s i t i o n

C 1 2 2 0 / 1

H o m e p o s i t i o n

R e a l

m e a s u r i n g

s y s t e m

M a c h i n e

m e a s u r i n g

s y s t e m

E n d o f t r a v e l s w i t c h

" P O S - L I M - P O S "

E n d o f t r a v e l s w i t c h

" P O S - L I M - N E G "

T r a v e r s i n g r a n g e

Fig. 3−11

Measuring systems for absolute positioning in default setting (C1225=0, C1227=0)

In default setting the reference point = machine zero = real zero (

¶ 3−34).

Reference point

l

The reference point is the reference for the connection" of the measuring systems with the
machine.

l

Is detected through referencing".

Machine measuring system

l

The permissible travelling range for the machine measuring system is determined through the
position limit values (C1223 and C1224).

l

The machine measuring system has a fixed reference to the machine because of the reference
point.

l

The reference point is detected by a reference run" or setting reference" and, usually, not
shifted later. (

¶ 3−46).

Real measuring system

l

All indications (e.g.: target positions, position setpoint, and actual position) refer to the real
zero of the real measuring system.

l

The real measuring system can be shifted by entering a reference measuring offset.

Advertising