65 variable table - acceleration (vtacc), Variable table − acceleration (vtacc), Function library – Lenze EVS9332xP User Manual

Page 301: Function blocks, 65 variable table − acceleration (vtacc)

Advertising
background image

Function library

Function blocks

3.5.65

Variable table − acceleration (VTACC)

3−273

l

EDSVS9332P−EXT DE 2.0

3.5.65

Variable table − acceleration (VTACC)

One function block (VTACC) is available.

Purpose

Stores the values for acceleration and deceleration. They serve as acceleration and deceleration
ramps in the positioning program.

VTACC-IN1

VTACC

C1354/1

C1355/1

VTACC-IN2

C1354/2

C1355/2

VTACC-IN3

C1354/3

C1355/3

VTACC-IN4

C1354/4

C1355/4

C1303/1

VTACC-OUT1

C1303/2

VTACC-OUT2

C1303/3

VTACC-OUT3

C1303/4

VTACC-OUT4

C1303/5

...

C1303/30

VTACC-No 1

VTACC-No 2

VTACC-No 3

VTACC-No 4

VTACC-No 5

VTACC-No 30

VTACC-No 31

VTACC-No 32

VTACC-No 33

VTACC-No 34

C1384/x

C1385/x

...

Fig. 3−218

Function block VTACC

Signal

Source

Note

Name

Type

DIS

DIS format

CFG

List

VTACC−IN1

ph

C1355/1

dec [inc]

C1354/1

3

·

Generates the absolute value for negative values.

·

When the values are > amax (C1250) the drive
moves with amax.

VTACC−IN2

ph

C1355/2

dec [inc]

C1354/2

3

VTACC−IN3

ph

C1355/3

dec [inc]

C1354/3

3

VTACC−IN4

ph

C1355/4

dec [inc]

C1354/4

3

VTACC−OUT1

ph

VTACC−OUT2

ph

VTACC−OUT3

ph

VTACC−OUT4

ph

Advertising