Function library

Positioning control

3.4.13

Program sets (PS)

3−84

l

EDSVS9332P−EXT DE 2.0

3.4.13.6

Set position value

Purpose

l

Shifting of the real measuring system during program processing

9300pos012

Fig. 3−33

Set position value

Function

l

Selection of the function Set position value" in PS under PS mode (C1311=5).

l

The position setpoint (POS−SETPOS) is set to the target position selected in the PS.

l

The actual position value (POS−ACTPOS) is set in order to keep the actual following error (no
jerk).

l

Setting the position value shifts the real zero; the actual reference offset (C1220/7) is changed.
The actual reference offset does no longer correspond to the input value under C1225.

l

The real zero can be shifted within the position limiting values (C1223, C1224). When
exceeding these limits the error message P08" (actual offset out of range) is set.