Prg. fct. wait for input, Function library – Lenze EVS9332xP User Manual

Page 113

Advertising
background image

Function library

Positioning control

3.4.13

Program sets (PS)

3−85

l

EDSVS9332P−EXT DE 2.0

3.4.13.7

Prg. fct. Wait for input"

Purpose

PS processing will not be continued before the selected digital input (POS−PFI) shows the level
required.

9300pos013

Fig. 3−34

Diagram − Wait for input

Function

l

Selection of any PFI under C1318/x

l

Selection of the required level under C1319/x.

l

GDC input: Programming" dialog

l

Default setting: not active