Homing modes 6 and 7, Function library, Positioning control – Lenze EVS9332xP User Manual

Page 81

Advertising
background image

Function library

Positioning control

3.4.8

Homing

3−53

l

EDSVS9332P−EXT DE 2.0

3.4.8.7

Homing modes 6 and 7

Purpose

l

Homing in all positioning modes (C1210 = 0, 1, 2).

l

Use of touch probe if the index pulse does not appear at the same place in a reproducible
form due to the mechanical constellation. The index signal can also be mechanically shifted
after a motor exchange.

l

The homing switch (POS−REF−MARK) must be in direction of the movement.

Travelling to TP signal via homing switch

Mode 6: Traversing direction to the positive end of the travel range limit switch

Set C1213 = 6.

Home position

TP signal

Homing switch (POS-REF-MARK)

9300pos054

Fig. 3−19

Move to TP signal via POS−REF−MARK

The following settings are necessary:

l

Select terminal for TP initiator via C1214.

– C1214 = 1

¢ terminal X5/E1.

– C1214 = 2

¢ terminal X5/E2.

– C1214 = 3

¢ terminal X5/E3.

– C1214 = 4

¢ terminal X5/E4 (This setting is recommended by LENZE).

l

Select edge of the TP input via C1215.

– C1215 = 0

¢ LOW−HIGH edge.

– C1215 = 1

¢ HIGH−LOW edge.

Function sequence

l

Move to the home position with homing speed (C1242) towards positive end of travel range
limit switch overtravelling the homing switch.

l

After leaving the homing switch the reference point is determined by the TP signal. TP signals
that occurred before are ignored.

l

The drive can be on the homing switch before homing.

Mode 7: Traversing direction to negative end of travel range limit switch

Set C1213 = 7.

Function sequence

l

As "Traversing direction to positive end of travel range limit switch", but the drive moves
towards the negative end of travel range limit switch.

Advertising