Control characteristic, Function library, Function blocks – Lenze EVS9332xP User Manual

Page 266

Advertising
background image

Function library

Function blocks

3.5.51

Process controller (PCTRL1)

3−238

l

EDSVS9332P−EXT DE 2.0

3.5.51.1

Control characteristic

l

In the default setting, the PID algorithm is active.

l

The D−component can be deactivated by setting code C0224 to zero. Thus, the controller
becomes a PI−controller (or P−controller if the I−component is also switched off).

l

The I−component can be switched on or off online via the PCTRL−I−OFF input. For this, the
input is assigned a digital signal source (e.g. one of the freely assignable digital input
terminals). If the I−component is to be switched off permanently, the input is assigned the
signal source "FIXED1".

– PCTRL−I−OFF = HIGH switches off the I−component

– PCTRL−I−OFF = LOW switches on the I−component

l

The reset time is parameterised via C0223.

l

The P−gain can be set in different ways. The function providing the P−gain is selected under
C0329:

– C0329 = 0

The P−gain is entered under C0222.

– C0329 = 1

The P−gain is entered via the PCTRL−ADAPT input. The input value is led via a linear
characteristic. The slope of the characteristic is set under C0222 (upper limit) and C0325
(lower limit). The value under C0222 is valid if the input value = +100 % or −100 %. The value
under C0325 applies if the input value is 0 %.

0

100 %

PCTRL−ADAPT

V

p

V

p1

V

p2

Input data:
V

p1

= C0222

V

p2

= C0325

Display value:
V

pact

= C0336

Fig. 3−185

Input of the P−gain via PCTRL−ADAPT input

– C0329 = 2

The P−gain is derived from the process setpoint PCTRL−SET. The setpoint is measured after
the ramp function generator and calculated by means of a characteristic with three
interpolation points.

V

p

V

p1

V

p2

V

p3

s

s

0

s

1

Input data:
V

p1

= C0222

V

p2

= C0325

V

p3

= C0326

s

0

= C0328

s

1

= C0327

Display value:
V

pact

= C0336

Fig. 3−186

P−gain derived from the PCTRL−SET process setpoint

– C0329 = 3

The P−gain is derived from the control difference and calculated by means of a characteristic
as for C0329 = 2.