Function library – Lenze EVS9332xP User Manual

Page 304

Advertising
background image

Function library

Function blocks

3.5.66

Variable table Piece number (VTPCS)

3−276

l

EDSVS9332P−EXT DE 2.0

Function

A total of 34 table positions are available.

l

Enter fixed values under C1304.

– 30 table positions (VTPCS−No1 ... VTPCS−No30) are available.

– Subcodes (C1304/1 ... C1304/30) define the table position number.

l

Enter variable values in VTPCS−INx.

– 4 table positions (VTPCS−No31 ... VTPCS−No34) are available.

– Signal input via function blocks.

– The values must be transmitted to the table positions before the corresponding program set

starts and accesses these values.

l

C1386 displays the values on the table positions.

– Select table position (C1386/1 ... C1386/34) with subcode.

l

For signals with percentage standardization at VTPCS−INx the conversion is performed
according the the formula:

VTPCS–INx [inc]

+ VTPCS–INx [%] @

16384 [inc]

100 %

Tip!

Entries into the processing table are necessary only if the FB inputs and outputs are used.

Advertising
This manual is related to the following products: