Phase displacement, Time slot for synchronisation via terminal, Phase displacement (chapter 3.5.62.3) – Lenze EVS9332xP User Manual

Page 293: Function library, Function blocks

Advertising
background image

Function library

Function blocks

3.5.62

Multi−axis synchronisation (SYNC1)

3−265

l

EDSVS9332P−EXT DE 2.0

3.5.62.3

Phase displacement

Phase displacement for synchronisation via system bus (SYNC TIME)

Code

Value

Function

C1122

0 ...10.000

ms

·

C1120 = 1

– Phase displacement between the sync telegram and the start of the internal control program.
– The parameters are set automatically depending on the parameter setting of the system bus (CAN).

·

C1120 = 2

– C1122 has no effect.

Phase displacement for synchronisation via terminal (PHASESHIFT)

Code

Value

Function

C1123/1

−1.000 ms
to
+1.000 ms

·

C1120 = 1

– C1123/1 has no effect.

·

C1120 = 2

– Phase displacement between the sync signal and the start of the internal control program (e. g. for

compensating the effects of signal propagation delays/dead times for the sync signal of the single
slave drives).

3.5.62.4

Time slot for synchronisation via terminal

Code

Value

Function

C1123/2

0 ... 1.000 ms

·

C1120 = 1

– C1123/2 has no effect.

·

C1120 = 2

– Definition of a "time slot" for the LOW−HIGH edges of the sync signal for the slave (defined via

C1121/1).

– If the sync signal sent by the master is within the "time slot", the SYNC1−STAT is switched to HIGH.

S Y N C - C y c l e ( C 1 1 2 1 / 1 )

S Y N C - W i n d o w ( C 1 1 2 3 / 2 )

S Y N C - S i g n a l

Fig. 3−211

Time slot" for the LOW−HIGH edges of the sync signal

Tip!

A jitter of up to ±200

μs on the LOW−HIGH edges of the sync signal is permissible. The size of the

jitter affects the parameter setting of the "time slot".

Advertising
This manual is related to the following products: