Purpose

This FB is used to limit signals to adjustable value ranges.

LIM1

LIM1-OUT

LIM1-IN

C0633

C0630

C0631

C0632

Fig. 3−160

Limiting element (LIM1)

Signal

Source

Note

Name

Type

DIS

DIS format

CFG

List

Lenze

LIM1−IN1

a

C0633

dec [%]

C0632

1

1000

LIM1−OUT

a

Function

l

If the input signal exceeds the upper limit (C0630), the upper limit is effective.

l

If the input signal falls below the lower limit (C0631), the lower limit is effective.

Tip!

The lower limit (C0631) must be smaller than the upper limit (C0630).