Positioning control

3.4.8

Homing

3−48

l

EDSVS9332P−EXT DE 2.0

3.4.8.3

Homing status (POS−REF−OK)

The homing status is indicated via the function block output POS−REF−OK" and displayed under
C1284.

The homing status is displayed as "Reference known" when the measuring systems have a defined
reference to the machine. Absolute positioning (

3−32) or (¶ 3−33) is only possible after a defined

reference has been created.

The output POS−REF−OK is set if

l

homing is completed,

l

the program function Set reference" is set,

l

the absolute value encoder is selected as position feedback (C0490 = 4).

l

Set Fb input POS−ABS−SET = 1.

l

C1210 = 2 (absolute positioning with saving)

The output POS−REF−OK is reset by

l

Start of homing

l

Writing to the following codes:

– C0011 (Nmax)

– C0490 (feedback system for the position controller)

Note:
Please take into consideration that codes C0490 and C0025 have an impact on each other.
A subsequent change of one of the codes overwrites the other.

– C1202 (Gearbox factor, numerator)

– C1203 (Gearbox factor, denominator)

– C1204 (Feed constant)

– C1207/1(Position encoder gearbox factor, numerator)

– C1207/2 (Position encoder gearbox factor, denominator)

– C1210 (Positioning mode)

l

The following errors occur:

– NMAX (limit speed from C0596)

– P12 (encoder limit exceeded)

– SD2 (resolver error) if resolver has been selected as position feedback system (C0490=0),

SD7 (absolute value encoder).

l

In relative positioning mode (C1210=1) if Prg−reset is carried out during a running positioning
process.