Function library

Positioning control

3.4.3

Positioning modes (C1210)

3−31

l

EDSVS9332P−EXT DE 2.0

Position resolution

l

Display via code C1205.
Display of the number of increments with which the units defined by the user are resolved
(incr/unit).

l

The position resolution can be used to check for rounding errors.

Calculation example:

C1301/1 = 100.2550 units (position value in VTPOS)

C1205 = 80.0000 inc/unit (position resolution)

Formula:

Feed

+ C1301[units] @ C1205[incńunit]

8020, 4 inc

+ 100, 2550 units * 80, 0000 incńunit

A difference of 0.4 inc results from every feed.