Function library

Positioning control

3.4.2

Machine parameters

3−26

l

EDSVS9332P−EXT DE 2.0

3.4.2

Machine parameters

Example

Purpose

l

The physical unit (e.g.: mm, m, degrees) for a unit" is defined via the entry of the machine
parameters.

Function

l

Entry of the gearbox ratio under C1202 and C1203, according to the nameplate data of the
gearbox.

C1202
C1203

5

Motor_speed

Getriebeabtriebsdrehzahl

l

Entry of the feed constant under C1204. Enter the number of units (e.g.: mm) to be fed during
one revolution at the gearbox output side.

l

Entry of the maximum motor speed (n

max

) under C0011. The limitation mainly applies to the

motor.

l

Entry of the maximum speed (v

max

) under C1240. Limitation mainly applies to the entire

machine. It should be set lower than the speed that can be attained at maximum motor speed.
The maximum speed v

max

is considered as the reference for all speed data in the VTVEL

variable table.

v

max

v n

max

@

v

k

60

@ i

C1240 v C0011 @ C

1204

@ C1203

60

@ C1202

l

Entry of the maximum acceleration (a

max

) under C1250.

The maximum acceleration is considered as the reference for all acceleration data given in per
cent in the VTACC variable table.