Homing

3−52

l

EDSVS9332P−EXT DE 2.0

Move to homing switch, reverse and move to reference point

Mode 4: Traversing direction to the positive end of the travel range limit switch

Set C1213 = 4.

1

?

Home position

Zero pulse / Zero position

Reference switch
(POS-REF-MARK)

9300pos034

Fig. 3−18

Move to POS−REF−MARK, reverse and move to reference point

Function sequence

l

Move towards travel range limit switch with homing speed C1242 up to homing switch
(case

0).

l

Reverse there and move to the reference point. The homing switch must be assigned during
the entire homing process!

l

The reference point is at the first zero pulse / zero position of the position encoder after leaving
the homing switch.

l

If the drive is already positioned on the homing switch before homing it is reversed
immediately (case

1).

Mode 5: Traversing direction to negative end of travel range limit switch

Set C1213 = 5.

Function sequence

l

Like mode 4, but the drive traverses in negative direction of travel range limit switch.