39 freely assignable input variables (fevan), Freely assignable input variables (fevan), Function library – Lenze EVS9332xP User Manual

Page 223: Function blocks

Advertising
background image

Function library

Function blocks

3.5.39

Freely assignable input variables (FEVAN)

3−195

l

EDSVS9332P−EXT DE 2.0

3.5.39

Freely assignable input variables (FEVAN)

Purpose

Transfer of analog signals to any code. At the same time, the FB converts the signal into the data
format of the target code.

FEVAN1-IN

C1098

C1096

C1093
C1094

CTRL

+

+

C1095

S&H

C1099/1

FEVAN1-LOAD

C1097/1

C1090

Code/Subcode

(Cxxxx/yy)

C1092

C1091

FEVAN1-BUSY

FEVAN1

1

C1099/2

FEVAN1-BUSY-IN

C1097/2

1

C1099/3

FEVAN1-FAIL-IN

C1097/3

FEVAN1-FAIL

Fig. 3−145

Freely assignable input variables (FEVAN1)

Signal

Source

Note

Name

Type

DIS

DIS format

CFG

List

FEVAN1−IN

a

C1098

dec

C1096

1

Input value

FEVAN1−LOAD

d

C1099/1

bin

C1097/1

2

A LOW−HIGH edge transmits the converted signal to the
target code.

FEVAN1−BUSY−IN

d

C1099/2

bin

C1097/2

2

HIGH = transmitting

FEVAN1−FAIL−IN

d

C1099/3

bin

C1097/3

2

High = transmission failed

FEVAN1−BUSY

d

HIGH = transmitting

FEVAN1−FAIL

d

HIGH = transmission failed
A LOW−HIGH edge at FEFAN1−LOAD sets FEFAN1−FAIL
= LOW.

C1090

Display of the converted signal

FEVAN2-IN

C1508

C1506

C1503
C1504

CTRL

+

+

C1505

S&H

C1509/1

FEVAN2-LOAD

C1507/1

C1500

Code/Subcode

(Cxxxx/yy)

C1502

C1501

FEVAN2-BUSY

FEVAN2

1

C1509/2

FEVAN2-BUSY-IN

C1507/2

1

C1509/3

FEVAN2-FAIL-IN

C1507/3

FEVAN2-FAIL

Fig. 3−146

Freely assignable input variables (FEVAN2)

Advertising
This manual is related to the following products: