Prg. fct. "branch 1, Prg. fct. branch 2, Function library – Lenze EVS9332xP User Manual

Page 116: Positioning control

Advertising
background image

Function library

Positioning control

3.4.13

Program sets (PS)

3−88

l

EDSVS9332P−EXT DE 2.0

3.4.13.11

Prg. fct. "Branch 1"

Purpose

Branching during program processing depending on the digital input signals (PFI).

Branching because of conditional query of two variables (<, >, = <=, >=):

1. Comparison of two variables with function block CMPPH" (7−109)

2. Connect the CMPPH output to the desired POS−PFI.

9300pos023

Fig. 3−37

Diagram − Branches 1 and 2

Function

l

Selection of any PFI under C1325/x.

l

Selection of the signal level under C1326/x.

l

Selection of the PS to be branched to PS under C1327/x (if the PFI has the level selected).

l

32 PFO are available (see POS−PFO).

l

GDC input: Programming" dialog

l

Default setting: not active

3.4.13.12

Prg. fct. Branch 2"

Purpose

See branch 1

Function

l

Selection of any PFI under C1334/x.

l

Selection of the signal level under C1335/x.

l

Selection of the PS to be branched to PS under C1336/x (if the PFI has the level selected).

l

32 PFO are available (see POS−PFO).

l

GDC input: Programming" dialog

l

Default setting: not active

Advertising