Function library

Function blocks

3.5.26

Drive control (DCTRL)

3−161

l

EDSVS9332P−EXT DE 2.0

Function

l

Quick stop (QSP)

l

Operation inhibited (DISABLE)

l

Controller inhibit (CINH)

l

TRIP set

l

TRIP reset

l

Change of parameter set (PAR)

l

Controller state

3.5.26.1

Quick stop (QSP)

The drive is braked to standstill via the deceleration ramp C105 and generates a holding torque.

l

The function can be controlled by three inputs

– Control word CAN−CTRL bit 3 of CAN−IN1

– Control word AIF−CTRL bit 3 of AIF−IN

– Control word C0135 bit 3

l

All inputs are linked by an OR−operation.

l

C0136/1 indicates the control word C0135

3.5.26.2

Operation inhibit (DISABLE)

In this state the drive cannot be started by the command: Controller enable. The power output stages
are inhibited. All controllers are reset.

l

The function can be controlled by three inputs

– Control word CAN−CTRL bit 8 of CAN−IN1

– Control word AIF−CTRL bit 8 of AIF−IN

– Control word C0135 bit 8

l

All inputs are linked by an OR−operation.

l

C0136/1 indicates the control word C0135