Function library, Function blocks, 39 freely assignable input variables (fevan) – Lenze EVS9332xP User Manual

Page 224

Advertising
background image

Function library

Function blocks

3.5.39

Freely assignable input variables (FEVAN)

3−196

l

EDSVS9332P−EXT DE 2.0

Signal

Source

Note

Name

Type

DIS

DIS format

CFG

List

FEVAN2−IN

a

C1508

dec

C1506

1

Input value

FEVAN2−LOAD

d

C1509/1

bin

C1507/1

2

A LOW−HIGH edge transmits the converted signal to the
target code.

FEVAN2−BUSY−IN

d

C1509/2

bin

C1507/2

2

HIGH = transmitting

FEVAN2−FAIL−IN

d

C1509/3

bin

C1507/3

2

HIGH = transmission failed

FEVAN2−BUSY

d

HIGH = transmitting

FEVAN2−FAIL

d

HIGH = transmission failed
A LOW−HIGH edge at FEFAN2−LOAD switches
FEFAN2−FAIL = LOW.

C1500

Display of the converted signal

FEVAN3-IN

C1518

C1516

C1513
C1514

CTRL

+

+

C1515

S&H

C1519/1

FEVAN3-LOAD

C1517/1

C1510

Code/Subcode

(Cxxxx/yy)

C1512

C1511

FEVAN3-BUSY

FEVAN3

1

C1519/2

FEVAN3-BUSY-IN

C1517/2

1

C1519/3

FEVAN3-FAIL-IN

C1517/3

FEVAN3-FAIL

Fig. 3−147

Freely assignable input variables (FEVAN3)

Signal

Source

Note

Name

Type

DIS

DIS format

CFG

List

FEVAN3−IN

a

C1518

dec

C1516

1

Input value

FEVAN3−LOAD

d

C1519/1

bin

C1517/1

2

A LOW−HIGH edge transmits the converted signal to the
target code.

FEVAN3−BUSY−IN

d

C1519/2

bin

C1517/2

2

HIGH = transmitting

FEVAN3−FAIL−IN

d

C1519/3

bin

C1517/3

2

High = transmission failed

FEVAN3−BUSY

d

HIGH = transmitting

FEVAN3−FAIL

d

HIGH = transmission failed
A LOW−HIGH edge at FEFAN3−LOAD sets FEFAN3−FAIL
= LOW.

C1510

Display of the converted signal

FEVAN4-IN

C1528

C1526

C1523
C1524

CTRL

+

+

C1525

S&H

C1529/1

FEVAN4-LOAD

C1527/1

C1520

Code/Subcode

(Cxxxx/yy)

C1522

C1521

FEVAN4-BUSY

FEVAN4

³1

C1529/2

FEVAN4-BUSY-IN

C1527/2

³1

C1529/3

FEVAN4-FAIL-IN

C1527/3

FEVAN4-FAIL

Fig. 3−148

Freely assignable input variables (FEVAN4)

Advertising
This manual is related to the following products: