Function library, Function blocks, 12 bcd decade switch (bcd) – Lenze EVS9332xP User Manual

Page 145: Bcd1

Advertising
background image

Function library

Function blocks

3.5.12

BCD decade switch (BCD)

3−117

l

EDSVS9332P−EXT DE 2.0

BCD1

C1700/2

C1703
C1704

CTRL

+

+

C1705

S&H

C1709/6

BCD1-LOAD

C1708/6

C1700/1

Code/Subcode

(Cxxxx/yyy)

C1707

C1706

BCD1-BUSY

BCD1

³1

C1709/7

BCD1-BUSY-IN

C1708/7

³1

C1709/8

BCD1-FAIL-IN

C1708/8

BCD1-FAIL

C1709/2

BCD1-DATA1

C1708/2

C1709/3

BCD1-DATA2

C1708/3

C1709/4

BCD1-DATA3

C1708/4

C1709/5

BCD1-DATA4

C1708/5

C1709/1

BCD1-READ

C1708/1

BCD-

LOGIC

BCD1-SIGN
BCD1-SEL1
BCD1-SEL2
BCD1-SEL3
BCD1-SEL4
BCD1-SEL5
BCD1-SEL6
BCD1-SEL7
BCD1-SEL8

BCD1-NEW-DATA

BCD1-EOT

BCD1-DATA-FLT

C1702

C1701

2

0

2

1

2

2

2

3

Fig. 3−73

Function block BCD1

Signal

Source

Note

Name

Type

DIS

DIS format

CFG

List

BCD1−DATA1

d

C1709/2

bin

C1708/2

2

Data input (LSB)

BCD1−DATA2

d

C1709/3

bin

C1708/3

2

Data input

BCD1−DATA3

d

C1709/4

bin

C1708/4

2

Data input

BCD1−DATA4

d

C1709/5

bin

C1708/5

2

Data input (MSB).

BCD1−READ

d

C1709/1

bin

C1708/1

2

Only required for handshake mode:

·

Signal must be applied at the controller for at least
2 ms.

·

LOW−HIGH edge starts the data transmission for a
BCD.

BCD1−LOAD

d

C1709/6

bin

C1708/6

2

LOW−HIGH edge = Write data to the code.

BCD1−BUSY−IN

d

C1709/7

bin

C1708/7

2

Generating a collective busy signal

BCD1−FAIL−IN

d

C1709/8

bin

C1708/8

2

Generating a collective fail signal

BCD1−SIGN

d

HIGH = Read sign.

BCD1−SEL1

d

HIGH = Read 1st BCD.

BCD1−SEL2

d

HIGH = Read 2nd BCD.

BCD1−SEL3

d

HIGH = Read 3rd BCD.

BCD1−SEL4

d

HIGH = Read 4th BCD.

BCD1−SEL5

d

HIGH = Read 5th BCD.

BCD1−SEL6

d

HIGH = Read 6th BCD.

BCD1−SEL7

d

HIGH = Read 7th BCD.

BCD1−SEL8

d

HIGH = Read 8th BCD.

BCD1−NEW−DATA

d

HIGH = BCD accepted, transmit next BCD.

BCD1−EOT

d

HIGH = all BCDs read or "CANCEL" recognised.

BCD1−DATA−FLT

d

HIGH = BCD code (see chapter 3.5.12.1).

BCD1−BUSY

d

HIGH = Data are being transmitted to code.

BCD1−FAIL

d

HIGH = Data transmission to code is faulty.

Advertising