Function library, Function blocks, 39 freely assignable input variables (fevan) – Lenze EVS9332xP User Manual
Page 225
Function library
Function blocks
3.5.39
Freely assignable input variables (FEVAN)
3−197
l
EDSVS9332P−EXT DE 2.0
Signal
Source
Note
Name
Type
DIS
DIS format
CFG
List
FEVAN4−IN
a
C1528
dec
C1526
1
Input value
FEVAN4−LOAD
d
C1529/1
bin
C1527/1
2
A LOW−HIGH edge transmits the converted signal to the
target code.
FEVAN4−BUSY−IN
d
C1529/2
bin
C1527/2
2
HIGH = transmitting
FEVAN4−FAIL−IN
d
C1529/3
bin
C1527/3
2
HIGH = transmission failed
FEVAN4−BUSY
d
−
−
−
−
HIGH = transmitting
FEVAN4−FAIL
d
−
−
−
−
HIGH = transmission failed
A LOW−HIGH edge at FEFAN4−LOAD sets FEFAN4−FAIL
= LOW.
−
−
C1520
−
−
−
Display of the converted signal
FEVAN5-IN
C1538
C1536
C1533
C1534
CTRL
+
+
C1535
S&H
C1539/1
FEVAN5-LOAD
C1537/1
C1530
Code/Subcode
(Cxxxx/yy)
C1532
C1531
FEVAN5-BUSY
FEVAN5
³1
C1539/2
FEVAN5-BUSY-IN
C1537/2
³1
C1539/3
FEVAN5-FAIL-IN
C1537/3
FEVAN5-FAIL
Fig. 3−149
Freely assignable input variables (FEVAN5)
Signal
Source
Note
Name
Type
DIS
DIS format
CFG
List
FEVAN5−IN
a
C1538
dec
C1536
1
Input value
FEVAN5−LOAD
d
C1539/1
bin
C1537/1
2
A LOW−HIGH edge transmits the converted signal to the
target code.
FEVAN5−BUSY−IN
d
C1539/2
bin
C1537/2
2
HIGH = transmitting
FEVAN5−FAIL−IN
d
C1539/3
bin
C1537/3
2
HIGH = transmission failed
FEVAN5−BUSY
d
−
−
−
−
HIGH = transmitting
FEVAN5−FAIL
d
−
−
−
−
HIGH = transmission failed
A LOW−HIGH edge at FEFAN5−LOAD sets FEFAN5−FAIL
= LOW.
−
−
C1530
−
−
−
Display of the converted signal
FEVAN6-IN
C1548
C1546
C1543
C1544
CTRL
+
+
C1545
S&H
C1549/1
FEVAN6-LOAD
C1547/1
C1540
Code/Subcode
(Cxxxx/yy)
C1542
C1541
FEVAN6-BUSY
FEVAN6
³1
C1549/2
FEVAN6-BUSY-IN
C1547/2
³1
C1549/3
FEVAN6-FAIL-IN
C1547/3
FEVAN6-FAIL
Fig. 3−150
Freely assignable input variables (FEVAN6)