Switching points, Function library, Function blocks – Lenze EVS9332xP User Manual

Page 281

Advertising
background image

Function library

Function blocks

3.5.59

Switching points (SP)

3−253

l

EDSVS9332P−EXT DE 2.0

3.5.59.1

Switching points

l

The switching points can be set in two ways:

– Mode 1: Start and end point

– Mode 2: Centre point with switching range

l

The switching points are entered via the variable table VTPOS.

– Direct input of the switch−on and switch−off points or centre point and range in VTPOS.

l

If the value at SPx−L−IN is within the range of the switching points set, SPx−STATx switches
HIGH

l

In factory setting, SPx−L−IN is connected to the actual position value (POS−ACTPOS) of the FB
POS.

– Therefore, the switching points refer to the distance traversed by the motor.

Assignment of the switch−on and switch−off points for SP1 (see also Fig. 3−199):

Code

Subcode

Switching point

Output FB

C1641

1

IN1−1

SP1−STAT1

2

IN1−2

...

...

...

...

C1641

15

IN8−1

SP1−STAT8

16

IN8−2

Assignment of the switch−on and switch−off points for SP2 (see also Fig. 3−200):

Code

Subcode

Switching point

Output FB

C1651

1

IN1−1

SP2−STAT1

2

IN1−2

...

...

...

...

C1651

15

IN8−1

SP2−STAT8

16

IN8−2

Mode 1: Start and end point

C1645 = set 0 (SP1)

C1655 = set 0 (SP2)

SPx-L-IN

SPx-L-IN

SPx-L-IN

SPx-STAT1

SPx-STAT2

SPx-STAT8

IN1-1

IN1-2

IN2-1

IN2-2

IN8-1

IN8-2

HIGH

LOW

HIGH

LOW

HIGH

LOW

Fig. 3−201

Switch−on and switch−off points for SPx−STAT1, SPx−STAT2 and SPx−STAT8

Advertising