Ps mode, Function library, Positioning control – Lenze EVS9332xP User Manual

Page 105

Advertising
background image

Function library

Positioning control

3.4.13

Program sets (PS)

3−77

l

EDSVS9332P−EXT DE 2.0

3.4.13.1

PS mode

Purpose

l

Selection of which positioning or special function is to be carried out in the PS.

Function

l

GDC input: Programming" dialog

l

Factory setting: No positioning or special function

l

Input under PS mode (C1311):

Value

Program functions

0

No positioning or special function

1

Absolute PS

2

Relative PS

3

Homing

4

Set homing value

5

Set position value to target position (C1312)

6

Absolute PS; TP positioning with E01

7

Absolute PS, TP positioning with E02

8

Absolute PS, TP positioning with E03

9

Absolute PS, TP positioning with E04

11

Relative PS, TP positioning with E01

12

Absolute PS, TP positioning with E02

13

Relative PS, TP positioning with E03

14

Relative PS, TP positioning with E04

16

Acceptance of home position (C1227)

30

Stand−by operation, cancel with STDBY−STP

31

Stand−by operation, cancel with TP E01 and traversing of the residual distance

32

Stand−by operation, cancel with TP E02 and traversing of the residual distance

33

Stand−by operation, cancel with TP E03 and traversing of the residual distance

34

Stand−by operation, cancel with TP E04 and traversing of the residual distance

Advertising
This manual is related to the following products: