Function library, Working with function blocks, 3 connecting function blocks – Lenze EVS9332xP User Manual

Page 39: Remove connections

Advertising
background image

Function library

Working with function blocks

3.1.3

Connecting function blocks

3−11

l

EDSVS9332P−EXT DE 2.0

Remove connections

l

Since a source can have several targets, there may be additional, unwanted signal
connections.

l

Example:

– In the basic configuration C0005 = 1000, ASW1−IN1 and AIN2−OUT are connected.

– This connection is not automatically removed by the settings described above! If you do not

want this connection, remove it.

+ −

*

/

x/(1−y)

C0600

x
y

ARIT2

ARIT2−OUT

C0602/1

"200%

C0602/2

ARIT2−IN1

ARIT2−IN2

C0601/1

C0601/2

62

AOUT1

C434/1

+

+

AOUT1−IN

AOUT1−GAIN

AOUT1−OFFSET

C0434/3

C0434/2

C0431

C0433

C0432

3

4

AIN2

+

+

AIN2−OUT

AIN2−GAIN

AIN2−OFFSET

C0409/1

C0409/2

C0407

C0408

C0108/1

C0109/1

C0027/2

C0026/2

ASW1−IN1

C0812/1

1

0

C0812/2

ASW1−SET

ASW1−IN2

ASW1

ASW1−OUT

C0813

C0810/1

C0810/2

C0811

FIXED0

FIXED0%

NSET−NADD

Fig. 3−4

Removing connections in a configuration

1. Remove connection between ASW1−IN1 and AIN2−OUT:

– Select C0810/1 using

z or y.

– Change to the parameter level using PRG.

– Select the constant FIXED0% (selection number 1000) using

z or y.

– Confirm using SH + PRG

– Change to the code level again using PRG.

Now, the connection is removed.

2. Save new configuration, if desired:

– If you do not want to lose the modifications after mains disconnection, save the new signal

configuration under C0003 in one of the parameter sets.