Function library, Function blocks – Lenze EVS9332xP User Manual

Page 226

Advertising
background image

Function library

Function blocks

3.5.39

Freely assignable input variables (FEVAN)

3−198

l

EDSVS9332P−EXT DE 2.0

Signal

Source

Note

Name

Type

DIS

DIS format

CFG

List

FEVAN6−IN

a

C1548

dec

C1546

1

Input value

FEVAN6−LOAD

d

C1549/1

bin

C1547/1

2

A LOW−HIGH edge transmits the converted signal to the
target code.

FEVAN6−BUSY−IN

d

C1549/2

bin

C1547/2

2

HIGH = transmitting

FEVAN6−FAIL−IN

d

C1549/3

bin

C1547/3

2

High = transmission failed

FEVAN6−BUSY

d

HIGH = transmitting

FEVAN6−FAIL

d

HIGH = transmission failed
A LOW−HIGH edge at FEFAN6−LOAD sets FEFAN6−FAIL
= LOW.

C1540

Display of the converted signal

Function

l

Conversion of the read data via:

– Numerator, denominator.

– Offset.

l

Selection of a target code for the read data.

Codes for the conversion of the data read and for the selection of the target code

Selection of the target code

Function block

Numerator

Denominator Offset

Code

Subcode

Examples

FEVAN1

C1093

C1094

C1095

C1091

C1092

FEVAN2

C1503

C1504

C1505

C1501

C1502

FEVAN3

C1513

C1514

C1515

C1511

C1512

FEVAN4

C1523

C1524

C1525

C1521

C1522

FEVAN5

C1533

C1534

C1535

C1531

C1532

FEVAN6

C1543

C1544

C1545

C1541

C1542

Data transmission

FEVANx-FAIL

FEVANx-BUSY

FEVANx-LOAD

Correct transmission

Wrong transmission

Fig. 3−151

Signal flow

Transmission errors may occur if

l

no target code is available,

l

no target subcode is available,

l

the data transmitted are out of the target code limits,

l

the target code is inhibited since it may only be written if the controller is inhibited. Inhibit the
controller (see code table).

Advertising
This manual is related to the following products: