Complete bcd reading, Function library – Lenze EVS9332xP User Manual

Page 152

Advertising
background image

Function library

Function blocks

3.5.12

BCD decade switch (BCD)

3−124

l

EDSVS9332P−EXT DE 2.0

3.5.12.6

Complete BCD reading

1

2

3

+/-

MSB

LSB

BCDx-SIGN

BCDx-SEL1

BCDx-SEL2

BCDx-SEL3

BCDx-DATA1

BCDx-DATA2

BCDx-DATA3

BCDx-DATA4

9300

BCDx-SEL4

Fig. 3−78

Cancel after the 3rd absolute value digit (diode circuit)

Function

Reading can be shortened if BCDs are not required.

l

The FB does not read the following BCDs if the value A

hex

(1010

bin

) for "ABORT" is transmitted

after a BCD has been read. The reading stops with the identification of "ABORT".

l

In the case of the abort via a value digit, the least significant bit (LSB) is to be assigned with
"ABORT", because the reading sequence stops at the least significant bit.

l

In the handshake mode, "CANCEL" should be identified at the beginning of the data
transmission (see also the following chapter).