Application examples

4.1

Example 1: Dosing system

4−6

l

EDSVS9332P−EXT DE 2.0

Basis: Basic configuration 20200

Terminal assignment

Inputs

Function 1

Function 2

Function 3

Outputs

Function

X5/E1

Manual jog in negative direction

X5/A1

Reference known

X5/E2

Manual jog in positive direction

X5/A2

Setpoint position reached

X5/E3

Program start

PS function (PFI 31)

X5/A3

Ready for operation

X5/E4

Homing switch

PS function (PFI 31)

X5/A4

PS function (POS−PFO1)

X5/E5

Trip reset

Program reset

Manual jog

Assignment of CAN1

Inputs

Function

Outputs
CAN−OUT1.

Function

W1

Actual speed value

D1

Actual position

CAN status word (bit 0.... bit15)
1: Pulse inhibit 2: Reference known 4: M

max

(Iow active)

5: Target position reached 6: n_actual = 0
7: Controller inhibit CINH
12: Fault warning 13: Fault message
14: Fault quick stop
15: Ready for operation

Assignment of CAN2

Inputs
CAN−IN2.

Function 1

Function 2

Function 3

Outputs
CAN−OUT2.

Function

B0

PS function (POS−PFI1)

Program stop

B0

Trip

B1

PS function

Program reset

B1

Program completed

B2

PS function

Program start

Manual jog off

B2

Traversing speed reached
(acceleration completed)

B3

PS function

Start homing / manual

B3

PS function (POS−PFO4)

B4

PS function

End of stand−by

B4

PS function

B5

PS function

New travel profile
parameters

B5

PS function

B6

PS function

No position control

B6

PS function

B7

PS function

Cancel PS

B7

PS function

B8 − B28

PS function

B8 − B28

PS function

B29

PS function (POS−PFI30)

B29

PS function

B30

PS function

B30

PS function

B31

PS function

B31

PS function (POS−PFO32)

Assignment of CAN3

Input

Function

Output

Function

CAN−IN2.D1

Special functions

Input

Function

Output

Function

C0471.B1

Activate S−profiles