Function library

Function blocks

3.5.29

Digital frequency ramp function generator (DFRFG)

3−173

l

EDSVS9332P−EXT DE 2.0

3.5.29.2

Quick stop

Removes the drive from the network and brakes it to standstill.

l

Activate with DFRFG−QSP = HIGH.

l

Set deceleration time via C0753.

l

Store the setpoint phase detected at DFRFG−IN.

l

Approach the setpoint phase via the profile generator after resetting the quick stop request.

t

DFRFG-IN

C0752

C0751

C0751

DFRFG-QSP

t

DFRFG-OUT

C0753

Fig. 3−126

Quick stop DFRFG

3.5.29.3

Ramp function generator stop

Maintains the state of the profile generator during operation.

l

Activate with DFRFG−STOP = HIGH

l

Output of the last state at DFRFG−OUT.

l

Store the setpoint phase detected at DFRFG−IN.

l

Approach the setpoint phase via the profile generator after resetting the stop request.

t

DFRFG-IN

C0752

DFRFG-STOP

t

DFRFG-OUT

Fig. 3−127

Ramp function generator stop