7Ć6

TYPICAL BNC

CONNECTOR

FERRULE ON

ANVIL OF

CRIMPING DIE

SHOULDER ON

CONNECTOR BODY

BUTTS AGAINST DIE

Figure 7.7 Ć Connector Installation Step 9 for RGĆ59/U Cable

Step 10. Hold the assembly in place, and close the crimp tool

handles until the ratchet releases.

Step 11. Remove the crimped assembly from the crimping dies.

The connector is now attached to the coax cable, as

shown in figure 7.8.

CRIMPED FERRULE

Figure 7.8 Ć Connector Attached to RGĆ59/U Cable