5 disconnecting a network drop – Rockwell Automation 57C570 AutoMax PC3000 User Manual User Manual

Page 239

Advertising
background image

21Ć7

Step 6.

Install the new RackĆMounted Transceiver following the

instructions provided in chapter 8. If the transceiver rack

is full, install another rack following the instructions

provided in chapter 8 and connect the transceivers as

shown in figure 21.5.

Step 7.

Resume network operation.

1

2

3

4

5

6

7

8

9 10 P/S

Drop 9

. . .

Drop 1

N

E

T

W

O

R

K

N

E

T

W

O

R

K

Drop 10

N

E

T

W

O

R

K

(New)

1

2

3

P/S

Hub 1 (New)

Hub 2

N

E

T

W

O

R

K

Figure 21.5 Ć Adding a Network Drop

21.2.5

Disconnecting a Network Drop

Use one of the following methods to disconnect a drop from the

AutoMax network. Note that you do not need to stop network

operation when you disconnect a drop from the network.
D Disconnect the drop cable from the Network module.
D Disconnect the fiberĆoptic cable from the StandĆAlone

Transceiver.

D Disconnect the fiberĆoptic cable from the RackĆMounted

Transceiver.