5Ć13

Step 9.

In the Edit Input/Output Range dialog box, change the

range to the next available Input/Output range by using

the Value list box. Make sure there are no device conflicts.

Step 10. Save your changes by clicking OK; exit the PC3000

Properties dialog box by clicking OK.

Step 11. When prompted by the Creating a Forced Configuration

dialog box, click Yes.

Step 12. Close the System Properties and Control Panel.

5.8.3

Adding the PC3000 Processor Card's Address to

the SYSTEM.INI File

You must edit the SYSTEM.INI file, located in the directory where

Windows 95 is installed, to add a reference to the PC3000 Processor

card.
Step 1.

Using a text editor, open the SYSTEM.INI file that is

located in the directory where Windows 95 is installed.

Step 2.

Locate the section [386Enh].

Step 3.

Add this additional line to the [386Enh] section:

EMMExclude=MEM1-MEM2

.

Where:

MEM1 = the beginning address of the next

PC3000 Processor card
MEM2 = the ending address of the next

PC3000 Processor card

Example

: EMMExclude=CA00-CBFF

NOTE: Although Windows 95 displays the address range in

five digits, you must enter the address as four digits. Do not

enter the fifth digit in the SYSTEM.INI file.

Step 4.

Add a comment to this address that documents the serial

number of the Processor card. For example:

EMMExclude = CA00-CBFF //(serial number)

Step 5.

Save and close the SYSTEM.INI file.