Rockwell Automation 57C570 AutoMax PC3000 User Manual User Manual

Page 119

Advertising
background image

8Ć7

8.5

Connecting a FiberĆOptic Cable Between a

StandĆAlone Transceiver and a

RackĆMounted Transceiver

WARNING

TURN OFF AND LOCKOUT OR TAG POWER TO BOTH THE RACK CONTAINING

THE NETWORK COMMUNICATIONS MODULE AND THE TRANSCEIVER

(RACKĆMOUNTED OR STANDĆALONE) BEFORE VIEWING THE FIBERĆOPTIC

CABLE OR TRANSMITTER UNDER MAGNIFICATION. VIEWING A POWERED

FIBERĆOPTIC TRANSMITTER OR CONNECTED CABLE UNDER MAGNIFICATION

MAY RESULT IN DAMAGE TO THE EYE. FOR ADDITIONAL INFORMATION,

REFER TO ANSI PUBLICATION Z136.1Ć1981. FAILURE TO OBSERVE THIS

PRECAUTION COULD RESULT IN BODILY INJURY.

CAUTION: Do not damage the ends of the fiberĆoptic cable connectors by touching

them or dropping them. Do not use factoryĆcompressed air to clean the fiberĆoptic ports

or connectors because the air may contain impurities that could scratch them. Failure

to observe this precaution could result in damage to or destruction of the equipment.

Use the following procedure to connect a fiberĆoptic cable between

a StandĆAlone Transceiver and a RackĆMounted Transceiver:
Step 1.

Remove the dust caps from the fiberĆoptic ports on the

StandĆAlone and the RackĆMounted Transceivers. Clean

the ports with a lintĆfree cloth moistened with isopropyl

alcohol or a can of compressed air. Save the dust caps.

All fiberĆoptic connectors and ports, when not in use,

should be covered with dust caps.

Step 2.

Remove the dust caps from the fiberĆoptic cable's

connectors. Use a lintĆfree cloth moistened with isopropyl

alcohol or a can of compressed air to clean the cable's

connectors.

Step 3.

Attach the cable's connectors to the ports as follows:
D PanelĆMounted Transceiver T" port: blue fiberĆoptic

wire

D PanelĆMounted Transceiver R" port: orange

fiberĆoptic wire

D RackĆMounted Transceiver T" port: orange fiberĆoptic

wire

D RackĆMounted Transceiver R" port: blue fiberĆoptic

wire

Note that the fiberĆoptic wires are colorĆcoded. Typically,

the wires are orange and blue. The wires used in your

installation may be of a different color, but they should be

installed in the same manner as described here. Verify

that the transmit connector of one unit is connected to the

receive connector of the other unit. Note that both of the

fiberĆoptic wires are the same.

Advertising
This manual is related to the following products: