3Ć8

Drop Cable and Communications

Passive Tap

The drop cable and the

Communications Passive Tap (tap) are

used to connect the AutoMax PC3000

to the coaxial cable. The drop cable

(M/N 57C381) is a threeĆfoot long

multiconductor cable with two 9Ćpin

DĆshell connectors at either end. It

connects the PC3000 to the tap.

The tap (M/N 57C380) provides two

BNCĆjack connectors for connection

to the coaxial cables and terminating

loads. A 9Ćpin DĆshell connector is

provided for connection to the drop

cable. The tap has two fault isolation

resistors in series with the

transmission line to prevent a

malfunctioning PC3000 from affecting

other drops on the network.

PASSIVE TAP

COMMUNICATIONS CARD

NETWORK

BNCĆ2

BNCĆ1

9ĆPIN DĆSHELL

CONNECTOR

.218" DIAMETER

MOUNTING HOLE

4.56" CENTER MOUNTING

HOLE TO CENTER

MOUNTING HOLE

Coaxial Cable

The DCSĆNET network uses two types

of coaxial cable, RGĆ59/U or RGĆ11/U.

Cable specifications are provided in

Appendix C. Refer to section 3.3.2 for

information about selecting the

appropriate cable.

INSULATION

CONDUCTOR

SHIELD

OUTER JACKET

BNC Plug Connector

Cable segments are terminated with

BNC plug connectors for attachment

to the taps. Reliance Electric

recommends the dualĆcrimp, BNC

plug connectors manufactured by

AMP, Inc., or an equivalent.

CONTACT

FERRULE