Connect the Kinetix 7000 Drive System

Chapter 4

External Shunt Module
Connections

External active shunt modules listed in the table on page 156 are compatible with
Kinetix 7000 drives. Follow these guidelines when wiring your external active
shunt module kit.

Refer to Shunt Resistor on page

37

for important wiring

recommendations.

Refer to

Appendix B

for the Kinetix 7000 drive interconnect diagrams.

Refer to the installation instructions provided with your shunt module.

SERCOS Fiber-optic Cable
Connections

This procedure assumes you have your Logix SERCOS interface module/PCI
card and Kinetix 7000 drive mounted and are ready to connect the fiber-optic
cables.

The SERCOS fiber-optic ring is connected using the SERCOS receive (Rx) and
transmit (Tx) connectors.

See page

65

to locate the SERCOS connectors on your Kinetix 7000 drive. See

the figure below to locate the connectors on your SERCOS interface module or
PCI card.

Plastic cable is available in lengths up to 32 m (105 ft). Glass cable is available in
lengths between 50 m (164 ft) and 200 m (656 ft).

IMPORTANT

When tightening screws to secure the wires to the DC bus terminals, see

Table 36

on page

90

for torque values.

IMPORTANT

When connecting Kinetix 7000 drives, use at least a 2090-SCEP1-0, 1 m (3
ft) or longer cable.

Larger drives may require longer cables.