Precharge Capacities of the
Regenerative Power Supply

Internal (built-in) and external precharge capacities of the regenerative power
supply (RPS) are listed below.

Product Dimensions

This section provides a quick reference table to common dimensions for Kinetix
7000 drives (height, width, depth, and mounting hole locations), and outline
drawings with dimensions related to the specific frame sizes.

Attribute 8720MC-RPS065Bx-HV2

8720MC-RPS190Bx

Rated Output kVa (750V DC bus)

(1)

45

133

DC Amperes Continuous

(1)

64

190

DC Amperes Peak (1 minute)

(1)

96 285

Built-in Capacitor

1900 μF

7600 μF

Built-in Resistor (Resistance/W)

7000 μF (22 Ohms/120 W)

25000 μF (10 Ohms/400 W)

External Resistor (Min Resistance)

(2)

(3)

110000 μF (20 Ohms)

165000 μF (10 Ohms)

External Circuit (Min Resistance)

(3)

220000 μF (4.7 Ohms)

495000 μF (1.5 Ohms)

(1) For 8720MC-RPS065-HV2 and 8720MC-RPS190, you may have up to two slave units with a master unit. Multiply these values by the number of slave units.
(2) Use this case only when the bus capacitance exceeds the internal precharge rating. You must use the specified resistor. Calculate rated wattage and surge

resistivity for that resistor. See the 8720MC Regenerative Power Supply Installation Manual, publication

8720MC-RM001

, for configuration details.

(3) Use this case only when the bus capacitance exceeds the external resistor rating. You must use the specified resistor. Calculate rated wattage and surge

resistivity for that resistor. See the 8720MC Regenerative Power Supply Installation Manual, publication

8720MC-RM001

, for configuration details.

IMPORTANT

Large levels of load capacitance may require modification of the 8720
regenerative power supply internal precharge/discharge circuit.

See the Wiring instructions in the 8720MC Regenerative Power Supply
Installation Manual, publication

8720MC-RM001

, for information on how

to determine the appropriate precharge/discharge resistance power value
(Ohms/Watt) to accommodate the capacitance of your system.