Connect the Kinetix 7000 Drive System

Chapter 4

The following fiber-optic cable examples are shown using ControlLogix
modules. CompactLogix modules connect in the same way, however the ring
cannot include more than four drives.

Figure 61 - Fiber-optic Cable Connections to ControlLogix/CompactLogix Modules

You can also mount the two Logix SERCOS modules in two separate chassis, or
you can mount them in the same chassis.

SERCOS interface TM

Tx (rear)

Rx (front)

OK

CP

Kinetix 6000 System

1756-MxxSE SERCOS interface Module

Receive

Receive

Transmit

Transmit

SERCOS Fiber-optic Ring

Kinetix 7000 Drive System

Transmit

Receive

Logix Chassis
(ControlLogix is shown)

IMPORTANT

Clean the fiber-optic cable connectors prior to installation. Dust in the
connectors can reduce signal strength.

See the Fiber-optic Cable Installation and Handling Instructions,
publication

2090-IN010

, for more information.