Customer-supplied 24V DC Power Supply Notes (HPK-series motors)

HPK-series motors require a customer-supplied 460V AC single-phase

supply, rather than a 24V DC supply. However, the brake current ratings
required by HPK-series motors are higher than the contact rating of the
GPR connector. Therefore, if using an HPK-series motor with a brake, it is
recommended that a customer-supplied, external interposing relay or
equivalent circuit be used. See

Figure 85

below.

The contact connected to GPR1+ and GPR1- is rated 2 Amps inductive

@ 250V AC/30 VDC maximum.

See the Kinetix Motion Control Selection Guide, publication

GMC-SG001

for HPK-series motor brake ratings.

Figure 85 - Customer-supplied HPK-Series Motor Brake Wiring Example

HPK-Series Motor Blower Connections

The HPK-series motor blower must be used to ensure proper motor

performance.

The blower connections can use either a Star (460 V AC) or Delta (230V

AC) three-phase configuration. See the HPK-Series Asynchronous Servo
Motor Installation Instructions, publication

HPK-IN001

, for connection

diagrams.

HPK-series Motors with a brake and without a brake have different blower

assemblies and, therefore, have different connection and electrical
characteristics.

The HPK-series motor has a conduit box with terminals/leads for external

power connections.

See the Kinetix Motion Control Selection Guide, publication

GMC-SG001

for HPK-series motors blower voltage and current

specifications.

BR+

BR-

A

C

3
2
4
1

GPR1-
GPR1+
COM
24VDC

24V DC

Supply

+ -

C1

C1

*Dashed lines

denote customer

supplied components.

L1 L2

Kinetix 7000

Drive

HPK-Series Motor

460V AC

Supply

Advertising