Rockwell Automation 2099-BMxx Kinetix 7000 High Power Servo Drive User Manual User Manual

Page 147

Advertising
background image

Rockwell Automation Publication 2099-UM001D-EN-P - December 2012

147

Troubleshoot the Kinetix 7000 Drive System

Chapter 6

Table 57 - Logix/Drive Fault Behavior Definitions

Logix Fault Message
(HIM)

Error
Code

Description

Drive Fault Action/
Attribute

RSLogix
Programmable
Fault Action?

MotorOvertempFault
(Motor Overtemp)

E04

(1)

The motor thermal switch was tripped.
Firmware I

2

t protection does not generate a fault, rather it dynamically folds back

current when 110% of motor rating is reached. Setting the Motor Thermal fault action
to Status Only will bypass this function.

STOP MOTION / Motor
Thermal

Yes

DriveOvercurrentFault
(Power Fault)

E05

An instantaneous overcurrent was detected in the inverter power section

SHUTDOWN

No

HardOvertravelFault
(+/- Hard Overtravel)

E06

Axis moved beyond the physical travel limits in the positive/negative direction. This
fault can be configured for status only.

STOP MOTION / Hard
Overtravel

Yes

MotFeedbackFault
(Motor Feedback Loss)

E07

The feedback wiring is open, shorted or missing.

DISABLE DRIVE

No

BusUndervoltageFault
(Bus Under Voltage)

E09

With three-phase present, the DC bus voltage is below limits.
The trip point is 800V DC for 460 drives.

SHUTDOWN

No

DC bus voltage is below limits when any axis on common-bus follower was enabled.

DriveOvervoltageFault
(Bus Overvoltage)

E10

The DC bus voltage is above limits.
The trip point is 800V DC for 460 drives.

SHUTDOWN

No

MotFeedbackFault
(Illegal Hall State)

E11

State of Hall feedback inputs in incorrect.

DISABLE DRIVE

No

SoftOvertravelFault
(+/- Software Overtravel)

E16

Axis position exceeded maximum software setting in the positive/negative direction.
This fault can be configured for status only.

STOP MOTION / Soft
Overtravel

Yes

OverSpeedFault
(Overspeed Fault)

E18

Axis speed has reached 150% of the maximum rated setting. The 100% trip point is
dictated by the lesser of the user velocity limits or the motor rated base speed.

DISABLE DRIVE

No

PositionErrorFault
(Follow Error)

E19

Axis position error limit has been exceeded. This fault can be configured for status only.

STOP MOTION /
Position Error

Yes

MotFeedbackFault
(Mtr Fdbk AQB)

E20

Motor encoder has encountered an illegal state transition.

DISABLE DRIVE

No

AuxFeedbackFault
(Aux Feedback Comm)

E21

Communication was not established with an intelligent (Stegmann) encoder on the
Auxiliary feedback port.

STOP MOTION

No

DriveOvertempFault
(Drive Overtemperature Fault)

E23

An IPM thermal protection fault occurred.

DISABLE
Drive Thermal

Yes

MotFeedbackFault
(Motor Feedback Comm)

E30

Communication was not established with an intelligent (Stegmann) encoder on the
motor feedback port.

STOP MOTION

No

GroundShortFault
(Ground Fault)

E34

Excessive ground current in the converter was detected.

SHUTDOWN

No

DriveUndervoltageFault
(Precharge Fault)

E35

The converter precharge cycle has failed.

SHUTDOWN

No

PowerPhaseLossFault
(Phase Loss Flt)

E37

One or more phases of the input ac power is missing.
Axis was enabled when main (three-phase) power was removed.
Common bus follower axis was enabled when dc bus power was removed.

SHUTDOWN/ STOP
MOTION

No

SERCOSFault
(SERCOS Ring Flt)

E38

The SERCOS ring is not active after being active and operational.

STOP MOTION

No

DriveHardFault
(Self Sense Flt)

E39

Self-sensing commutation fault detected

DISABLE DRIVE

No

DriveEnableInputFault
(Drive Enable Flt)

E43

Generated when Enable input switches off when drive is enabled.

STOP MOTION

Yes

DriveHardFault
(Safe-Off HW Flt)

E49

Safe-off function mismatch. Drive will not permit motion. Refer to the Kinetix Safe-off
Feature Safety Reference Manual, publication

GMC-RM002

, for more information. Only

applies to drives with Safe-off feature.

SHUTDOWN

No

SERCOSFault
(SERCOS Same ADDR)

E50

Duplicate node address detected on SERCOS ring.

STOP MOTION

No

DriveHardFault
(Ifbk HW Fault)

E54

Current feedback hardware fault detected.

SHUTDOWN

No

Advertising