Figure 73 – Rockwell Automation 2099-BMxx Kinetix 7000 High Power Servo Drive User Manual User Manual

Page 164

Advertising
background image

164

Rockwell Automation Publication 2099-UM001D-EN-P - December 2012

Appendix B

Interconnect Diagrams

Figure 73 - Kinetix 7000 Drive AC Powered with a 8720MC-RPS065BM Regenerative Power Supply

IMPORTANT

This configuration requires the power regenerative mode settings as described in the 8720MC Regenerative Power Supply
Installation Manual, publication

8720MC-RM001

, and setting of the power tab in RSLogix 5000 software is set to the

appropriate bus regulator catalog number. Common mode capacitors should be disconnected on DC common bus drives.

STOP*

START (RPS On)*

CR1*

CR1*

E/N

R

S T

MC

STOP*

START (Drive Main Power On)*

CR2*

CR2*

CR2*

M1* Note 4

L1

L2

L3

TB1

L1 AUX

L2 AUX

L3 AUX

PR1

PR2

PR3

MC1

MC2

TB2

TB1

DC+

DC-

MC

RST

PWR

0V

24V

COM

IP

RDY

FR

FR

TB3

5

6

PE

R

S

T

8

7

TB

REGEN COM

REGEN OK

GPIO

DC+

DC-

TB

GPR2+

GPR

*1

20V AC

or 24V DC

L1

L2

L3

M1*

GPR2-

Dr

ive Stop

-Start String

*

*Bo

nde

d Ca

bin

et

Ground Bus

*12

0V/240V AC

or

24

V DC

*Line Reactor (8720MC for

RPS unit)

RPS Stop-Start String

*

*Bond

ed Cabi

net

Ground Bus

* In

dicate

s User Su

pp

lied

Com

po

nen

t

*Three

-pha

se In

pu

t

(+10/-15%)

380V AC RMS, 50 Hz or 460V AC RMS, 6 Hz

See Note 1

*Lin

e Reactor

(1321-3R type, 3% compatible

with Kinetix 7000 drive)

*Th

ree-

ph

ase Conta

cto

r

(M1 in

Con

tro

l String)

*Circuit Breaker

* V

aristo

r

*In

put

Fusing

* Sing

le-

ph

ase

AC Line Fil

ter

*H

arm

on

ic

Filter

CR1*

Kinetix 700

0 Dr

ive

209

9-BM

xx-S

DC Bus

Connections

Control Stop String See Note 8

AC Inp

ut

Connections

*MC AUX

*M1 AUX

* Th

ree-

ph

ase

AC Line Filter

*T

hr

ee

-p

ha

se

AC Line Filter

24

V ENABLE

ENABLE

24V COM

IOD

1

2

Th

ree-

ph

as

e

Contactor (MC)

36

0° Shi

eld

ing

of

Power Wiring

Required to Comply with

EMC Requirements

Lin

e Co

nt

act

or

(M1 on Stop String)*

Ad

dition

al co

nn

ec

tion

s re

qu

ired

,

but not shown in this diagram: 1. +24V DC Control Power 2. Motor Feedback, Brake (if used), and Power 3. Drive I/O and Communications

Power Connections

*Mo

tion

Co

ntr

ol

Stop-Start String (from PLC or other control string)

Regenerative Power Supply

87

20M

C-R

PS065BM

Fault Relay Contact

*In

put

Fusing See Note 3

Motion

Control I/O*

See Note 11

Advertising