Kinetix 7000 Connector Data

Chapter 3

SERCOS Connections

Two fiber-optic connectors (transmit and receive) are provided on the Kinetix
7000 drive.

Table 24 - SERCOS Communications Specifications

Safe-off (SO Connector)

Kinetix 7000 drives provide safety functions and system integrity.

The Kinetix 7000 drive ships with a (9-pin) wiring-plug header having a motion-
allowed jumper installed in the safe-off (SO) connector. With the motion-
allowed jumper installed, the safe-off feature is disabled.

For safe-off wiring information, see the Kinetix Safe-off Feature Safety Reference
Manual, publication

GMC-RM002

.

Figure 41 - Safe-Off, Motion-allowed Jumper

Control Power Specifications

The following table provides specifications for the Control Power (CP)
connector.

Specification

Description

Data Rates

4 and 8 Mbps

Node Addresses

01…99

(1)

(1) Node addresses for additional axes on the same system are assigned by sequentially incrementing each additional axis. See Node

Addressing Examples on page

108

for more information.

1

1 2

3 4

5 6

7 8

9

FDBK2+

FDBK2-

FDBK1+

FDBK1-

ENABLE2+

ENABLE-

ENABLE1+

SO_24VDC

SO_COM

SO

FDBK2+

FDBK2-

FDBK1+

FDBK1-

ENABLE2+

ENABLE-

ENABLE1+

SO_24VDC

SO_COM

SO

Motion-allowed Jumper

Wiring Plug Header

Safe-off
(SO) Connector

Attribute

Value

Auxiliary DC input voltage

24V DC, 3 A max, range 18…30 V DC