Rockwell Automation Publication 2099-UM001D-EN-P - December 2012

167

Interconnect Diagrams

Appendix B

Figure 76 - Dual 8720MC-RPS065Bx Regenerative Power Supplies to a Single Kinetix 7000 Drive

IMPORTANT

This configuration requires the power regenerative mode settings as described in the 8720MC Regenerative Power Supply
Installation Manual, publication

8720MC-RM001

, and setting of the power tab in RSLogix 5000 software is set to the

appropriate bus regulator catalog number. Common mode capacitors should be disconnected on DC common bus drives.

DC+

DC-

TB

24V DC

ENABLE

IOD

5

6

GPR2+

GPR

8

7

REGEN COM

REGEN OK

GPIO

STOP*

START (RPS On)*

CR1*

L1

L2

L3

TB1

L1 AUX

L2 AUX

L3 AUX

PR1

PR2

PR3

MC1

MC2

TB2

TB1

DC+

DC-

L1

L2

L3

TB1

L1 AUX

L2 AUX

L3 AUX

PR1

PR2

PR3

MC1

MC2

TB2

TB1

DC+

DC-

1

2

E/N

E/N

P

N

MC1*

MC

RST

PWR

0V

24V

COM

IP

RDY

FR

FR

TB3

Ad

dition

al co

nn

ec

tion

s re

qu

ired

,

but not shown in this diagram: 1. +24V DC Control Power 2. Motor Feedback, Brake (if used), and Power 3. Drive I/O and Communications

CR1*

GPR2-

CR1*

MC2*

CB2*

Bon

ded

Cab

ine

t

Ground Bus*

Circui

t

Breaker (CB2)*

Input Fusing* See Note 2

Th

ree-p

ha

se

Contactor (MC2)

Ha

rm

on

ic

Filter*

Va

ris

tor

*

* Ind

icat

es U

ser

Su

pp

lie

d Co

mp

on

en

t

*120

V/240V AC

or

24V DC

MC2

Th

ree-p

ha

se

Contactor (MC1)

Ha

rm

on

ic

Filter*

Va

ris

tor

*

Sin

gle

-p

hase

Contactor See Note 4

Fault Relay Contact

DC Bus

Connections

Kinetix 700

0 Dr

ive

2099-BM

xx-S

Axis

n

Con

trol

Stop String See Notes 6 and 8

Dig

ital I

/O

and Power Connections

DC Line Fuses*

DC Lin

e

Fuses*

12

0V A

C

or 24V DC*

RPS St

op-Start Str

ing

DC Bus Co

nne

cti

ons

*Line Reactor (8720MC for

RPS unit)

*DC Line

Fuses

(see table in Appendix A)

*Line Reactor (8720MC for

RPS unit)

*T

hr

ee

-p

ha

se In

put

(+10/-15%) 380V AC RMS, 50 Hz or 460V AC RMS, 60 Hz See Note 1

Three-phase AC Line Filter for Main Power*

See Note 3

Bon

ded

Cab

ine

t

Ground Bus*

Circui

t

Breaker (CB1)*

Input Fusing* See Note 2

Th

ree

-p

ha

se

AC Line Filter for Main Power*

Sing

le-ph

ase

AC Line Filter*

Sing

le-ph

ase

Contactor* See Note 4

MC1

Slave

Regenerative Power Supply

8720MC-RPS065BS

Master

Regenerative Power Supply

8720MC-RPS065BM

PIFS CN2

PIFS CN3

See Note 10

CB2*

Motion

Control I/O*

See Note 11