Rockwell Automation Publication 2099-UM001D-EN-P - December 2012

51

Kinetix 7000 Connector Data

Chapter 3

Control Power (CP) Terminal Block Connections

Kinetix 7000 drives must be wired to a 24V DC control power source through
the Control Input Power (CP) connector. The Control Power input terminal is
located on the bottom of the drive as illustrated in

Figure 19 on page 44

.

Figure 26 - Control Power (CP) Terminal Block Detail

Table 17 - Control Power (CP) Terminal Block

Power Terminal Block (PTB) Connections

The power terminals are located behind the lower front panel of the drive. The
figures below identify the input power, motor power, DC bus, ground, and
cooling fan input terminals.

The 2099-BM09-S or 2099-BM10-S drives (frame 5), and the 2099-BM11-S or
2099-BM12-S drives (frame 6) provide connections for you to supply 120V AC
or 240V AC to power an internal cooling fan. The fan VA rating is 100 VA for
2099-BM09-S and 2099-BM10-S, and 138 VA for the 2099-BM11-S and 2099-
BM12-S drives.

The 2099-BM06-S, 2099-BM07-S, and 2099-BM08-S drives (frame 3) use the
internal power supply for fan power and thus no terminals are provided.

IMPORTANT

An external power supply provides the ability to retain control of the drive’s
logic independent of its bus power status.

Terminal

Description

Signal Name

1

Control Power 24V DC Input

CP_24VDC

2

CP_COM

CP

CP_24VDC

CP_COM

Terminal Block

(on bottom of drive)

Label

(on front of drive)

Advertising