Power specifications, E power specifications – Rockwell Automation 2099-BMxx Kinetix 7000 High Power Servo Drive User Manual User Manual

Page 150

Advertising
background image

150

Rockwell Automation Publication 2099-UM001D-EN-P - December 2012

Appendix A

Specifications and Dimensions

Power Specifications

This section contains power specifications for the Kinetix 7000 drive.

Attribute

2099-BM06-S

2099-BM07-S

2099-BM08-S

2099-BM09-S

2099-BM10-S

2099-BM11-S

2099-BM12-S

AC input voltage

342…528V AC rms three-phase (380…480V nom)

AC input frequency

47…63 Hz

Bandwidth

(1)

Velocity loop
Current loop

500 Hz
1300 Hz

500 Hz
500 Hz

PWM frequency

4 kHz

2 kHz

Main AC input current

Nom (rms)
Max inrush (A peak)

36.7 A
18.0 A

47.7 A
18.0 A

59.6 A
18.0 A

90.1 A
96.0 A

117 A
118 A

169 A
141 A

233 A
141 A

DC input voltage

450…750V DC

DC input current

42.9 A

55.7 A

69.7 A

105 A

137 A

204 A

281 A

Control power input Voltage

18…30V DC (24V DC, nom)

Control power DC input current

Nom (rms)
Maximum inrush (rms)

3.3 A
6.0 A

Continuous output current (rms)

40.0 A

52.0 A

65.0 A

96.0 A

125 A

180 A

248 A

Continuous output current (0-pk)

56.0 A

73.0 A

92.0 A

135 A

176 A

254 A

351 A

Peak output current (rms)

3 s duration
60 s duration

68.0 A
51.0 A

80.0 A
60.0 A

104 A
78.0A

154 A
115 A

163 A
138 A

312 A
234 A

372 A
273 A

Peak output current (0-pk)

3 s duration
60 s duration

96.0 A
72.0 A

113 A
84.8 A

147 A
110 A

217.7 A
162.6 A

230.5 A
195 A

441 A
331 A

526 A
386 A

Bus overvoltage

800V DC

Bus undervoltage

275…560V DC

(2)

Continuous power output, nom

22 kW

30 kW

37 kW

56 kW

75 kW

112 kW

149 kW

Continuous power output (Hp)

30 Hp

40 Hp

50 Hp

75 Hp

100 Hp

150 Hp

200 Hp

Maximum power cycles/minute

AC line
DC bus

4 per minute (pre-charge provided by drive)
2 per minute (DC pre-charge provided by the regenerative power supply)

DC bus discharge time

3 minutes after removal of main AC power

Efficiency

97.5%

Total capacitance

(3)

1800

μ

F

2400

μ

F

3000

μ

F

4500

μ

F

6000

μ

F

8400

μ

F

8400

μ

F

Short circuit current rating

200,000 A (rms) symmetrical

(1) Bandwidth values vary based on tuning parameters and mechanical components.
(2) Bus undervoltage will vary based on input line voltage.
(3) If DC input is supplied to 2099-BM09-S, 2099-BM10-S, 2099-BM11-S, or 2099-BM12-S drives, the precharge capability must be provided at the system level. Disconnect switches must not be used

between the input of the drive and a common DC bus without the use of an external precharge device.

Advertising