Figure 74 – Rockwell Automation 2099-BMxx Kinetix 7000 High Power Servo Drive User Manual User Manual

Page 165

Advertising
background image

Rockwell Automation Publication 2099-UM001D-EN-P - December 2012

165

Interconnect Diagrams

Appendix B

Figure 74 - 8720MC-RPS065BM Regenerative Power Supply to a Single Kinetix 7000 Drive

IMPORTANT

This configuration requires the power regenerative mode settings as described in the 8720MC Regenerative Power Supply
Installation Manual, publication

8720MC-RM001

, and setting of the power tab in RSLogix 5000 software is set to the

appropriate bus regulator catalog number. Common mode capacitors should be disconnected on DC common bus drives.

L1

L2

L3

TB1

L1 AUX

L2 AUX

L3 AUX

PR1

PR2

PR3

MC1

MC2

TB2

GPR2+

GPR

E/N

5

6

STOP*

START (RPS On)*

CR1*

CR1*

MC

TB1

DC+

DC-

MC

RST

PWR

0V

24V

COM

IP

RDY

FR

FR

TB3

8

7

REGEN COM

REGEN OK

GPIO

CR1*

DC Bus

Connections

*MC AUX

24V ENABLE

ENABLE

24V COM

IOD

1

2

Power Connections

Fault Relay Contact

GPR2-

TB

DC+

DC-

RPS Stop-

Start String*

*1

20V/240V AC

or

24V DC

* Ind

icates User Sup

pli

ed Co

mpon

ent

*Bon

ded

Cab

inet

Ground Bus

*V

aristor

*Th

ree-p

ha

se

AC Line Filter for Main Power See Note 3

*Ha

rm

on

ic

Filter

*Sin

gle

-phase

AC Line Filter See Note 3

*Line Reactor (8720MC for

RPS unit)

*Thre

e-pha

se In

pu

t

(+

10

/-15%)

38

0V AC RMS,

50

Hz

38

0V AC RMS,

50

Hz

See Note 1

*Thre

e-pha

se

Contactor

(MC)

*Circuit Breaker

*In

put

Fusing

Regenerati

ve

Power Suppl

y

8720M

C-

RP

S065BM

Kinetix 7000 Drive

2099-BM

xx-S

Ad

dition

al co

nn

ec

tion

s re

qu

ired

,

but not shown in this diagram: 1. +24V DC Control Power 2. Motor Feedback, Brake (if used), and Power 3. Drive I/O and Communications

See Note 4

See Notes 6 and 8

Motion

Control I/O*

See Note 11