Gpio – Rockwell Automation 2099-BMxx Kinetix 7000 High Power Servo Drive User Manual User Manual

Page 46

Advertising
background image

46

Rockwell Automation Publication 2099-UM001D-EN-P - December 2012

Chapter 3

Kinetix 7000 Connector Data

General Purpose I/O (GPIO) Terminal Block Connections

The following diagram and table provide the orientation and signal description
for the General Purpose Input/Output terminal block.

Figure 21 - Orientation for General Purpose I/O (GPIO) Terminal Block

Table 9 - General Purpose I/O (GPIO) Terminal Block

General Purpose Relay (GPR) Terminal Block Connections

The following diagram and table provide the orientation and signal description
for the General Purpose Relay terminal block.

Figure 22 - Orientation for General Purpose Relay (GPR) Terminal Block

Table 10 - General Purpose Relay (GPR) Terminal Block

Terminal

Description

Signal Name

1

Digital Output 1

Digital_Out_1

2

+24V DC for digital output 1 (customer-supplied)

DO_24VDC_1

3

+24V DC for digital output 2 (customer-supplied)

DO_24VDC_2

4

Digital Output 2

Digital_Out_2

5

Reserved

N/C

6

Reserved

N/C

7

Regenerative power supply OK (customer supplied)

Regen_OK+

8

Common for Regenerative power supply OK

Regen_OK-

Terminal

Description

Signal Name

1

24V DC customer-supplied power input for Relay 1

24VDC

2

Programmable N.O. Relay 1 output

GPR1+

3

Programmable Relay 1 common

GPR1-

4

24V DC customer-supplied power supply common

COM

5

Programmable N.O. Relay 2 output

GPR2+

6

Programmable Relay 2 common

GPR2-

DO1

DO1_24VDC

DO2

DO2_24VDC

N/C N/C

REGEN_OK+

REGEN_OK-

GPIO

GPR2-

COM

GPR2+

GPR1-GPR1+

24VDC

GPR

Note: The GPR terminal number
orientation is rotated 180 degrees relative
to the other I/O connectors.