Summary of changes, New and updated information – Rockwell Automation 2099-BMxx Kinetix 7000 High Power Servo Drive User Manual User Manual

Page 3

Advertising
background image

Rockwell Automation Publication 2099-UM001D-EN-P - December 2012

3

Summary of Changes

This manual contains new and updated information. Changes throughout this
revision are marked by change bars, as shown to the right of this paragraph.

New and Updated
Information

This table contains the changes made to this revision.

Topic

Page

Updated the Additional Resources with updated and new publications.

9

Updated the Typical System Diagrams to include updated catalog numbers for
Bulletin MPL motors, Bulletin MPM motors, and regenerative power supplies.

13

Added the Using Motion Analyzer to Determine Heat Dissipation information to the
Enclosure Selection section.

24

Added the mounting information from Chapter 3 - Mount the Kinetix 7000 Drive
System, to Chapter 2 - Install the Kinetix 7000 Drive System and removed Chapter 3.

39

Updated the Kinetix 7000 Front Panel Connectors and Displays, Kinetix 7000 Top
Panel Connectors and Switches, a
nd Kinetix 7000 Bottom Panel Connectors
illustrations and tables for clarity.

42

Updated the IOD connector pinouts in the Hardware Enable, Home and Positive and
Negative Overtravel circuit diagrams.

55

Added information on Reading Analog Input Voltage Values.

61

Updated information on configuring the General Purpose I/O regenerative power
supply OK signal.

64

Added

Figure 41

Safe-Off, Motion-allowed Jumper.

65

Updated the information in the Setting the Ground Jumper in Ungrounded Power
Configurations section.

78

Updated the Wire the Kinetix 7000 Drive Connectors section.

88

Added Flying-lead Feedback Cable Pinouts for the new 2090-XXNFMF-Sxx and 2090-
CFBMxDF-CDAFxx Feedback Cable.

95

Added illustrations to the Wire Feedback and I/O Connectors section.

95

Updated the information on External Shunt Module Connections to reflect
availability of certain shunt modules.

101

Updated the Node Addressing Examples to reflect current topologies.

108

Updated the steps and images in the Configure the Logix SERCOS interface Module
section to reflect the current software release.

110

Added the Configure Drive Parameters and System Variables section.

134

Added an explanation for the Drive Overtemperature Fault (E23) to the list of Error
Codes.

140

Updated the Specifications and Dimensions section to reflect current data and
specifications.

150

Added Korean Registration of Broadcasting and Communications Equipment
certification to the Certifications table.

154

Added the new External Shunt Modules section to Appendix A.

156

Updated the Interconnect Diagrams to reflect new cables and corrected connections
information.

161

Advertising