Rockwell Automation 2099-BMxx Kinetix 7000 High Power Servo Drive User Manual User Manual

Page 107

Advertising
background image

Rockwell Automation Publication 2099-UM001D-EN-P - December 2012

107

Configure and Startup the Kinetix 7000 Drive System

Chapter 5

5. Set the SERCOS optical power level to High using DIP switch 1.

Figure 64 - SERCOS DIP Switch Settings and Locations

6. Repeat Steps 4 and 5 for each Kinetix 7000 drive.

For This Optical Power Level

Set Switch 1

Low

OFF

High

ON

IMPORTANT

All drives on the SERCOS ring must have the same baud rate and power setting.

1

2

3

1

2

3

DIP Switches Set for
4 Mbps Applications
(high-power setting)

DIP Switches Set for
8 Mbps Applications
(high-power setting)

ON

OFF

SERCOS Baud Rate
and Optical Power Switches

SERCOS switch and connectors
(typical orientation around DPI connector)

ON

OFF

Switch in ON Position

Switch in OFF Position

Note: 8 Mbps setting shown.