Cm cap mov – Rockwell Automation 2099-BMxx Kinetix 7000 High Power Servo Drive User Manual User Manual

Page 79

Advertising
background image

Rockwell Automation Publication 2099-UM001D-EN-P - December 2012

79

Connect the Kinetix 7000 Drive System

Chapter 4

Removing the Ground Jumper on 2099-BM06-S, 2099-BM07-S, and
2099-BM08-S Drives

Figure 47

shows the location of the jumpers in 2099-BM06-S, 2099-BM07-S,

and 2099-BM08-S drives on the power chassis. The common mode capacitor
jumper is indicated by callout 1 (PEA) and the MOV jumper is indicated by
callout 2 (PEB).

Remove each jumper by carefully pulling it straight out.

Figure 47 - Ground Jumper Location on 2099-BM06-S, 2099-BM07-S, and
2099-BM08-S

BR1 BR2 DC+ DC- U/T1 V/T2 W/T3 R/L1 S/L2 T/L3

PE B

PE A

75C Cu Wire

3 AWG [25MM

2

] Max.

16 IN. LBS.
1.8 N-M

} TORQUE

WIRE
STRIP

CONTR

OL

PO

WER

AUX IN

+ –

SHLD

SHLD

PE

75C Cu Wire

6 AWG [10MM2] Max.

BR1 BR2

12 IN. LBS.
1.4 N-M

} TORQUE

PE A

PE B

CM Cap

MOV

1

2

Important: Do not discard or replace the grounding hardware.

Advertising