Safe-off (so) terminal block connections – Rockwell Automation 2099-BMxx Kinetix 7000 High Power Servo Drive User Manual User Manual

Page 50

Advertising
background image

50

Rockwell Automation Publication 2099-UM001D-EN-P - December 2012

Chapter 3

Kinetix 7000 Connector Data

Safe-off (SO) Terminal Block Connections

Figure 25 - Safe-off (SO) Terminal Block

Table 16 - Safe-off (SO) Terminal Block

Terminal

Description

Signal Name

1

Normally-closed monitoring contact for safety relay 2

FDBK2+

2

Return for safety relay 2

FDBK2-

3 Normally-closed

monitoring

contact for safety relay 1

FDBK1+

4

Return for safety relay 1

FDBK1-

5

Coil of safety relay 2

ENABLE2+

6

Common for safety relays 1 and 2

ENABLE-

7

Coil of safety relay 1

ENABLE1+

8

24V DC, 500 mA max., power for Safe Off circuit

SO_24VDC

9

Common for 24V power Safe off circuit

SO_COM

IMPORTANT

Terminals 8 and 9 (24V+ and Common) are only used by the motion-
allowed jumper. When using the Safe-off feature, the 24V supply must
come from an external source.