Positive and Negative Overtravel

The Positive and Negative Overtravel detection is provided by two optically
isolated (500V), single-ended, normally-closed, active high signals. Breaking the
24V DC input at either pin indicates an overtravel condition.

You can enable hard travel limits on the axis servo drive Limit tab in RSLogix.
Hard travel limits require power to both the positive and negative overtravel
inputs. You can monitor the positive and negative overtravel input status in the
axis servo drive tag.

Notes:

A status of “1” indicates a normally closed input and a drive ready for

movement.

Hard overtravel limits can only be selected in a linear conversion selection.

This input is level sensitive. See

Table 19

-

Digital Input Descriptions

and

Table 20

-

Digital Input Specifications

starting on page

54

for On/Off signal

voltages and current levels.

Kinetix 7000 drive Positive and Negative Overtravel functions and faults actions
are programmed through RSLogix software. Kinetix 7000 drive firmware
provides an additional 50ms of debounce.

The schematic below depicts the Positive and Negative Overtravel circuits. It is
provided as a reference only.

Figure 33 - Positive and Negative Overtravel Input Diagram

(1) +24V DC source (range) = 21.6…26.4V (supplied by the drive, not to exceed 300 mA total).

Maximum current input = 10 mA.

IMPORTANT

Overtravel limit input devices must be normally-closed.

ATTENTION: Overvoltage protection is not provided for the Positive and
Negative Overtravel input signal.

It is recommended to use the on drive power to power the Positive and Negative
Overtravel signals. If an external power source is used, you must take responsibility
to be sure that the voltage/current does not exceed the rating of the input.

2k

Ω

0.1

μ

F

511

Ω

VCC

INPUT

IO_COM

I/O SUPPLY

1k

Ω

Kinetix 7000 Drive

Customer-supplied Input Device

+24V DC

(1)

Positive Overtravel
or
Negative Overtravel

IOD-7, 10

IOD-9, 12

IOD-8, 9